SHORT COMMUNICATION Annals of Nuclear Medicine Vol, 15, No, 1 , 61-64, 2001 Validation of CBF measurement with non-invasive microsphere method (NIMS) compared with autoradiography method (ARG) Tatsuro KAMINAGA, Natsuko KUNIMATSU, Takashi CHIKAMATSU and Shigeru FURUI Department of Radiology, Teikyo University School of Medicine The purpose of this study is to examine the correlation of measured regional cerebral blood flow (rCBF) by means of a new microsphere method (non-invasive microsphere method), to the autoradiography (ARG) method, which is an established quantification method for 123-I-IMP brain SPECT. The non-invasive microsphere (NIMS) method and ARG method were simultaneously applied to 30 patients, and quantified rCBF maps were calculated with each method. A significant correlation (r = 0.70: p < 0.001 ) was detected between mCBF values calculated with the NIMS and ARG methods. This new method seems to reliably quantify rCBF with brain SPECT. Key words: 123-I-IMP (N-isopropyl-p-iodoamphetamine), regional cerebral blood flow, quantification, microsphere method, autoradiography method INTRODUCTION I-123 labeled N-isopropyl-p-iodoamphetamine (123-I-IMP) was developed by Winchell et al. and is used for estimating regional cerebral blood flow (rCBF).1,2 It has a higher first pass extraction fraction and negligible wash out from cerebral tissue just after the injection. 3,4 123-I-IMP is one of the most suitable commercially available SPECT tracers for quantification of rCBF with the microsphere method. Many quantification methods have been proposed for 123-I-IMP with arterial blood satnpling.3,5-8 Sugihara et al. and Miyazaki et al. have proposed a calculation method for cardiac output by first-pass transit of radiotracers.9,10 This new method is appropriate for quantification of organ blood flow on the basis of the microsphere model. Yonekura et al. reported a quantification method for rCBF with this new method, which has been named the non-invasive microsphere (NIMS) method. 11 Nakano et al. examined the accuracy of NIMS with reference to continuous arterial blood sampling.12 But, to the best of our knowledge, no other paper has focused on the comparison of the NIMS method with other quantification method. Received August 24, 2000, revision accepted November 16, 2000. For reprint contact: Tatsuro Kaminaga, M.D., Department of Radiology, Teikyo University School of Medicine, 2-11-1, Kaga, Itabashi-ku, Tokyo 173-8605, JAPAN. E-mail : kami@med.teikyo-u.ac.jp In this study, the accuracy of NIMS was examined by correlating it with the autoradiography (ARG) method.6 MATERIALS AND METHODS The NIMS and ARG methods were applied to 30 patients simultaneously (age; 47.3 +- 9.4, male/female; 18/12). Their clinical diagnoses/symptoms were 13 dizziness, 10 chronic fatigue syndrome, 7 headache. No patient has any disease affecting cardiac output and/or pulmonary flow. Figure 1 illustrates the procedure of the NIMS and ARG methods. A dose of 222 MBq 123-I-IMP (Nihon Medi-Physics Co. Ltd., Japan) was injected rapidly into the right cubital vein. Dynamic scans including both lungs and heart area were performed from just after the bolus injection of 123-I-IMP. We use MAXXUS (General Electric Co. Ltd., USA) equipped with low-energy high-resolution type collimator. Scan conditions were as fol-lows: scan time: 3 minutes, frames: 2 frames/second, view: anterior, matrix: 128 x 128. Hands selected regions of interest (ROIs) including whole lung and pulmonary artery and time-activity curves of both ROIs were obtained. The total pulmonary count at peak time: L(peak) was found, and the total pulmonary count 5 minutes after the injection: L(5) was calculated by exponential approximation with the pulmonary count data from L(2) to L(3). The lung washout rate 5 minutes after injection was calculated as {L(peak) - L(5)} / L(peak). The time-activity curve of the pulmonary artery was fitted to an exponential curve, and the area of this time-activity curve during the first pass was calculated (R). Cardiac output (CO) was calculated from R and the total injected dose of 123I-IMP after dead time correction, and the results of Doppler echocardiography were correlated according to the method of Sugihara et al.9 Correlated cardiac output (CO') was calculated as follows: CO' = 28.8 x CO0.634 From 4.5, 25 (before SPECT) and 51 (after SPECT) minutes after the injection, a brain planar image was taken with these conditions: scan time: 1 minute, view: anterior, matrix: 128 x 128. A ROI including the whole brain was drawn on a brain planar image by hand, and the total brain counts at 5 minutes after the injection: B(5), just before SPECT: B(before), and just after SPECT: B(after) were obtained. Brain SPECT was performed from 30 minutes after injection of 123I-IMP. The scan conditions were: scan time: 16 minutes, step: 30 seconds/step total 32 steps, prefilter: Butterworth (cut off; 0.45 cycle/cm, order; 10), backprojection-filter: ramp, matrix: 64 x 64, collimator: low-energy high-resolution type, gamma camera: MAXXUS. Regional CBF was calculated as follows I 11,13: rCBF = rSPC x CBF factor CBF factor (ml/100 g/min) = K x [B(5)/( B(before) + B(after) }/2] x CO' x D(1.04 g/ml) x 100/[Q x { 1 - L(5)/L(peak)}] rSPC: regional SPECT count K: Correlation factor of SPECT count to planar count that was measured in the phantom study with 123I-IMP Q: Total injected dose of 1231-IMP D: Density of cerebral parenchyma The factor K was the ratios of SPECT to total planar count and defined as the ratio of phantom SPECT count and difference between syringe counts before and after injection of 123I-IMP into phantom. We used an acryl syrindlical phantom (16 centimeters in diameter) which was filled with 37 MBq of 123I-IMP solution. The scan conditions of SPECT and planar image in the phantom study were identical to those of clinical SPECT and planar image. A deadtime correction was also performed on the basis of the phantom study. The total injected dose of 123I-IMP (Q) was regarded as the difference between the preinjection and post-injection syringe counts. Arterial blood sampling was done 10 minutes after the injection from the right cubital artery. The total blood count was measured with a well type scintillation counter (ARC 256, Aloka Co. Ltd., Japan). The standard input function of the ARG method proposed by Iida et al.6 was correlated with this count. Calculation of rCBF and construction of rCBF maps by the two methods were performed automatically with software supplied by the manufacturer (General Electric Co. Ltd., USA). The mean CBF (mCBF) was the mean rCBF of the right cerebral hemisphere at the level of the basal ganglia (Fig. 2). The significance of the correlation between mCBF values with the NIMS and ARG methods was examined by linear regression test. RESULTS The distribution of CO' is shown in Figure 3. Figure 4 shows the correlation between the NIMS and ARG methods. A significant correlation (r = 0.70: p < 0.001) was detected between mCBF values by the NIMS and ARG methods . DISCUSSION 123I-IMP is frequently used for estimating rCBF values. Various methods are proposed to quantify rCBF with 123I-IMP,3,5-8 most of which require arterial blood sampling, thereby limiting their clinical applicability. Among them, the NIMS method does not require arterial blood sampling. The NIMS method is based on the microsphere theory. A good correlation of the NIMS method to the microsphere method with continuous arterial blood samplingl2 ensured the accuracy of the former. The ARG method requires only a single arterial blood sampling and it can correlate back diffusion of 123I-IMP. Iida et al. reported a significant correlation (r = 0.85) between rCBF values calculated with the ARG method and those calculated with PET by H2150.6 In this study we compared the rCBF values obtained with the NIMS method with those obtained with the ARG method. A significant correlation (r = 0.70: p < 0.001) between the two methods again confirmed the accuracy of the NIMS method. Future improvements in the NIMS method will include correction to the lipophilic fraction of 123I-IMP, delayed washout of 1 231-IMP from the lungs, and uniformity of the bolus injection speed. 123I-IMP is metabolized in blood, and estimation and correlation of the lipophilic fraction of 123I-IMP are necessary for the NIMS method as with other quantification methods. The washout speed of 123I-IMP from the lungs differs among individuals 14 and this influences the rCBF values calculated with the NIMS method. As noted by Nakano et al.12 and Yonekura et al.,11 the CO value can be changed by the bolus injection speed. A too fast injection speed overestimates CO, and a too slow injection speed underestimates it. In conclusion, the NIMS method is a reliable method to quantify rCBF without arterial blood sampling. REFERENCES 1. Winchell HS, Baldwin RM, Lin TH. Development of I-123-labeled amines for brain studies: localization of 123I-iodophenylalkyl amines in rat brain. J Nucl Med 1980; 21: 940-946. 2. Winchell HS, Horst WD, Braun L, Oldendorf WH, Hattner R, Parker H. N-isopropyl-[123-I]p-iodoamphetamine: Single-pass brain uptake and washout; Binding to brain synapto-somes; and localization in dog and monkey brain. J Nucl Med 1980; 21 : 947-952. 3. Kuhl DE, Barrio JR, Huang SC, Selin C, Ackermann RF, Lear JL, et al. Quantifying local cerebral blood flow by N-isopropyl-p-[123I]iodoamphetamine (IMP) tomography. J Nucl Med 1982; 23: 196-203. 4. Lassen NA, Henriksen L, Holm S, Barry DI, Paulson OB, Vorstrup S, et al. Cerebral blood-flow tomography: xenon-133 compared with isopropyl-amphetamine-iodine-123: concise communication. J Nucl Med 1983; 24: 17-21. 5. Munaka M, Iida H. New Quantification of regional cerebral blood flow measurements by 123I-IMP SPECT with the rotating gamma camera. Theory and validation of the look-up table method. KAKU IGAKU (Jpn J Nucl Med) 1992; 29: 385-389. 6. Iida H. Itoh H, Nakazawa M, Hatazawa J, Nishimura H, Onishi Y, et al. Quantitative mapping of regional cerebral blood flow using Iodine-123-IMP and SPECT. J Nucl Med 1994; 35: 2019-2030. 7. Odano I, Ohkubo M, Takahashi N, Higuchi T. A new method of regional cerebral blood flow measurement using one-point arterial sampling based on the microsphere model with N-isopropyl-p-[123I]-iodoamphetamine SPECT. Nucl Med Commun 1994; 15: 560-564. 8. Fujioka H, Murase K, Inoue T, Ishimaru Y, Akamune A, Yamamoto Y, et al. A method for estimating the integral of the input function for the quantification of cerebral blood flow with 123I-IMP using one-point arterial blood sampling. Nucl Med Commun 1998; 19: 561-566. 9. Sugihara H, Yonekura Y, Miyazaki Y, Taniguchi Y. Estimation of cardiac output by first-pass transit of radiotracers. Ann Nucl Med 1999; 13: 299-302. 1O. Miyazaki Y, Kinuya S, Tonami N. Simple method to estimate cardiac output using first-pass data on RI angiography. KAKU IGAKU (Jpn J Nucl Med) 1994; 31 : 1539-1545 . 11 . Yonekura Y, Sugihara H, Taniguchi Y. Aoki E, Furuichi K, Miyazaki Y. Quantification of brain perfusion SPECT with N-isopropyl-p-iodoamphetamine using noninvasive microsphere method: estimation of arterial input by dynamic imaging. KAKU IGAKU (Jpn J Nucl Med) 1997; 34: 901-908 . 12. Nakano S, Matsuda H, Tanizaki H, Ogawa M. Miyazaki Y. Yonekura Y. Regional cerebral blood flow measurements by a noninvasive microsphere method using 123I-IMP: comparison with the modified fractional uptake method and the continuous arterial blood sampling method. KAKU IGAKU (Jpn J Nucl Med) 1998; 35: 209-218. 13. Nihon Medi-Physics Co Ltd. Handbook of NIMS method. Hyogo, Nihon Medi-Physics Co. Ltd., in Japanese, 1998: 1-14. 14. Yonekura Y, Fujita T, Nishizawa S, Iwasaki Y, Mukai T, Konishi J. Temporal changes in accumulation of N-isopropyl-p-iodoamphetamine in human brain: relation to lung clearance. J Nucl Med 1989; 30: 1977-1981.