Title虚血性心疾患に対する, 低レベル運動負荷併用dipyridamole負荷心筋SPECTの診断能 - 同一症例での運動負荷心筋SPECT所見との比較 -
Subtitle≪原著≫
Authors高尾祐治*, 村田啓*, 加藤健一**, 小野口昌久***, 大竹英二*, 趙圭一*
Authors(kana)
Organization*虎の門病院放射線科, **循環器センター内科, ***放射線部
Journal核医学
Volume28
Number4
Page361-370
Year/Month1991/4
Article原著
Publisher日本核医学会
Abstract「要旨」低レベル運動負荷併用dipyridamole負荷心筋SPECT (Dp法)の虚血性心疾患の検出に対する有用性について, 同一症例(28例)に施行した通常の運動負荷心筋SPECT (Ex法)所見と比較検討した. Dp法の視覚判定による病変検出能はEx法と同等以上(accuracy 71% vs 67%)だった. また集積低下の程度と再分布の程度はともにDp法の方が強かった. Washout rate (WR)による定量解析では, 正常対照例(Dp法10, Ex法8)におけるDp法での平均WR値がEx法と同等の高値となり, 症例によるばらつきも小さかった. 狭心症14例でのWRによる病変検出能はDp法の方が有意に高値だった(accuracy 86% vs 64%; p<0.05). これらの結果は, Dp法がEx法より優れており, ルーティンの負荷法として有用である可能性を示した. 胸部症状とST低下所見の発現頻度はいずれも高率で, Dp法による欠損には, 相対的血流増加の差のみでなく, 心筋虚血の誘発も関与している可能性が高いと考えられた.
Practice臨床医学:一般
Keywordsdipyridamole, ischemic heart disease, thallium myocardial SPECT, low level exercise washout rate.
English
TitleUsefulness of Thallium-201 Myocardial SPECT Using Dipyridamole Infusion Combined with Low Level Exercise for the Detection of the Ischemic Heart Disease - Comparison with SPECT Images by Maximum Physical Exercise in the Same Patients
Subtitle- Original Articles -
AuthorsYuji TAKAO*, Hajime MURATA*, Kenichi KATOH**, Masahisa ONOGUCHI*, Eiji OHTAKE*, Keiichi CHO*
Authors(kana)
Organization*Division of Nuclear Medicine, **Cardiovascular Center, Toranomon Hospital
JournalThe Japanese Journal of nuclear medicine
Volume28
Number4
Page361-370
Year/Month1991/4
ArticleOriginal article
PublisherTHE JAPANESE SOCIETY OF NUCLEAR MEDICINE
Abstract[Summary] To evaluate the usefulness of thallium-201 myocardial SPECT using dipyridamole infusion combined with low level exercise (Dp-method) for the detection of the ischemic heart disease, we performed both Dp-method and maximum physical exercise SPECT (Ex-method) in the same 28 patients, and compared the results obtained by the two methods. In the visual evaluation, the detectability of each stenotic coronary territory by Dp-method tended to be higher than that by Ex-method (accuracy 71% vs 67%). The severity of the defect and the degree of the redistribution were higher by Dp-method than those by Ex-method. In the washout rate (WR) analysis in 14 angina pectoris patients, the detectability (accuracy) by Dp-method was significantly higher than that by Ex-method (86% vs 64%; p<0.05). In comparison of mean WR values in normal subjects (10 cases for Dp-method and other 8 cases for Ex-method), mean WR by Dp-method was as high as that by Ex-method and the deviation of WR value among subjects was very small. This was probably due to the effect of the low level exercise. These results suggested that Dp-method was more excellent than Ex-method in the evaluation of the ischemic heart disease, and was a useful method of the daily routine work. The incidence of chest symptom and the electrocardiographic ST-depression was as high by Dp-method as that by Ex-method. The filling defects in Dp-method were thought to be induced not only by the difference in the relative increase of the myocardial perfusion, but also by the myocardial ischemia.
PracticeClinical medicine
Keywordsdipyridamole, ischemic heart disease, thallium myocardial SPECT, low level exercise washout rate.