Japanese |
Title | 81mKr持続静注法と99mTc-MAA肺血流分布によるV/V分布の測定 - 133Xe法との比較を中心に - |
Subtitle | 原著 |
Authors | 大谷洋一*, 間島寧興*, 森豊*, 島田孝夫**, 守谷悦男*, 川上憲司* |
Authors(kana) | |
Organization | *東京慈恵会医科大学放射線医学教室, **第三内科学教室 |
Journal | 核医学 |
Volume | 25 |
Number | 4 |
Page | 323-329 |
Year/Month | 1988/4 |
Article | 原著 |
Publisher | 日本核医学会 |
Abstract | 「要旨」 81mKr持続静注法と99mTc-MAAによる血流分布の差から, 単位肺容量当たりの換気量 (V/V (R) Q) を求めた. そして, 81mKr吸入法による換気分布と133Xe反復呼吸時の肺容量分布から求めたV/V (R) Vと比較し, V/V (R) QがV/Vを表わしていることを, 臨床例において実証した. 検査は坐位安静呼吸下に行った. 肺野を重力方向に6mm厚のスライスに分画し, 各スライスにおいてV/V (R) QとV/V (R) Vを求め, 両者の相関を求めた. 10例 (20肺) における相関係数は1例を除いて0.76〜0.95と高かった. これらの結果は, 81mKr溶液と99mTc-MAA静注法より求めたV/V (R) Qが, 局所のV/Vを表わしていると考えられる. 本法は, 133Xeを使わずに, V/Vが求められるという利点をもっている. |
Practice | 臨床医学:一般 |
Keywords | V/V distribution, Kr-81m, Tc-99m-MAA, Xe-133. |
English |
Title | A Measurement of V/V Distribution by Intravenous Injection of Kr-81m and Tc-99m-MAA - A Comparative Study with Xe-133 Inhalation Method - |
Subtitle | Original Articles |
Authors | Yoichi OHTANI*, Yasuoki MASHIMA*, Yutaka MORI*, Takao Shimada**, Etsuo MORIYA*, Kenji KAWAKAMI* |
Authors(kana) | |
Organization | *Department of Radiology, **The Third Department of Medicine, Jikei University of Medicine |
Journal | The Japanese Journal of nuclear medicine |
Volume | 25 |
Number | 4 |
Page | 323-329 |
Year/Month | 1988/4 |
Article | Original article |
Publisher | THE JAPANESE SOCIETY OF NUCLEAR MEDICINE |
Abstract | [Summary] Distribution of ventilation per unit lung volume (V/V) was measured by intravenous injection of Kr-81m and Tc-99m-MAA on 10 subjects having various pulmonary diseases. The distribution of V/V (R) Q obtained by this method was compared with that (V/V (R) V) obtained by the inhalation method of Kr-81m (V) and Xe-133 gas (V) . The study was performed in sitting position. Kr-81m solution and Tc-99m-MAA was injected continuously to the antecubital vein during tidal breathing. V and V on inhalation study was measured with Kr-81m gas and Xe-133 gas respectively. The lung field was divided in about 30 slices with 6 mm thickness from top to bottom. Relative distribution of V/V was compared between V/V (R) Q and V/V (R) V for each subject. Correlation coefficient was 0.76-0.95 in 20 lungs of ten subjects, except for one lung. This result suggests that the distribution of V/V measured by Kr-81m and Tc-99m-MAA represents regional V/V in the lung. This method is useful to measure V/V when Xe-133 is not available. |
Practice | Clinical medicine |
Keywords | V/V distribution, Kr-81m, Tc-99m-MAA, Xe-133. |