Japanese
Titlem- [131I] iodobenzylguanidine (I-131 MIBG) シンチグラフィーの褐色細胞腫の診断における診断能 : コンピュータ断層撮影, 超音波断層撮影との比較
Subtitle原著
Authors酒井美知子*, 田所匡典**, 牧野直樹**, 石垣武男**, 安部哲太郎**, 佐久間貞行**
Authors(kana)
Organization*中部労災病院放射線科, **名古屋大学医学部放射線科
Journal核医学
Volume24
Number1
Page7-14
Year/Month1987/1
Article原著
Publisher日本核医学会
Abstract「要旨」褐色細胞腫が疑われた28症例に30回のm-[131I]iodobenzylguanidine(I-131MIBG)シンチグラフィーを行った. そのうち確定診断の得られた24検査例についてI-131MIBGシンチグラフィーの意義と診断能についてコンピュータ断層撮影(CT), 超音波断層撮影(US)と比較し検討した. I-131MIBGのsensitivityは8/9(88.9%), specificityは15/15(100%), accuracyは23/24(95.8%)であった. 一方, CTのsensitivityは9/9(100%), specificityは10/15(66.7%), accuracyは19/24(79.2%)であり, USのsensitivityは8/9(88.9%), specificityは12/15(80.0%), accuracyは20/24(83.3%)であった. 褐色細胞腫の診断に際しI-131MIBGシンチグラフィーはCTに比べ腫瘍の大きさの面で限界があり, 今回の症例では検出限界は2.0×2.5×2.0cmであったが, CTやUSに比し, より特異性の高い検査法であることが示された.
Practice臨床医学:一般
KeywordsPheochromocytoma, Multiple endocrine neoplasia, I-131 MIBG, Computed tomography, Ultrasonography.
English
TitleDiagnostic Efficacy of m- [131I] Iodobenzylguanidine (I-131 MIBG) Scintigraphy in Locating Pheochromocytoma : Comparison with Computed Tomography and Ultrasonography
SubtitleOriginal Articles
AuthorsMichiko SAKAI*, Masanori TADOKORO**, Naoki MAKINO**, Takeo ISHIGAKI**, Tetsutaro ABE**, Sadayuki SAKUMA**
Authors(kana)
Organization*Department of Radiology, Chubu Rosai Hospital, **Department of Radiology, Nagoya University School of Medicine
JournalThe Japanese Journal of nuclear medicine
Volume24
Number1
Page7-14
Year/Month1987/1
ArticleOriginal article
PublisherTHE JAPANESE SOCIETY OF NUCLEAR MEDICINE
Abstract[Summary]Scintigraphic images using I-131 MIBG were reviewed in the 28 patients with suspected pheochromocytoma. The diagnostic efficacy of the I-131 MIBG scintigraphy for location of mass was discussed comparing with computed tomography (CT) and ultrasonography (US). The smallest size of the pheochromocytoma revealed by both I-131 MIBG scintigraphy and US was 2.0 × 2.5 × 2.0 cm. On the other hand, CT detected smaller mass, 1.0 × 1.5 × 0.4 cm in size. The sensitivity was 88.9% in I-131 MIBG scintigraphy, 100% in CT, and 88.9% in US. The specificity was 100% in I-131 MIBG, 66.7% in CT, and 80.0% in US. And the accuracy was 95.8% in I-131 MIBG, 79.2% in CT, and 83.3% in US. Thus I-131 MIBG scintigraphy was proved to be more sensitive than both CT and US for the location of pheochromocytoma, and is an available method for the first choice.
PracticeClinical medicine
KeywordsPheochromocytoma, Multiple endocrine neoplasia, I-131 MIBG, Computed tomography, Ultrasonography.

【全文PDF】