Title全身用リング型SPECT装置を用いたTl-201心筋ダイナミックスキャン
Subtitle《原著》
Authors小出治敏*, 米倉義晴*, 藤田透*, 鳥塚莞爾*, 野原隆司**, 不藤哲郎**, 神原啓文**, 河合忠一**, 小西裕***, 伴敏彦***
Authors(kana)
Organization*京都大学医学部附属病院放射線核医学科, **第三内科, ***心臓血管外科
Journal核医学
Volume23
Number11
Page1523-1531
Year/Month1986/11
Article原著
Publisher日本核医学会
Abstract「要旨」: 心筋のTl-201分布の経時的変化を調べる目的で, 全身用リング型多層SPECT装置を用いて, 虚血性心疾患を対象に運動負荷後ダイナミックSPECTスキャンを行った. 冠動脈造影で異常が見られなかった症例では静注後30分以内の早期からほぼ一定の速さでTl-201のwashoutが始まっており, また虚血心筋では正常例とは異なる種々の経時的変化が認められ, 心筋血流の状態を反映するものと考えられた. 心筋虚血の診断に早期のwashoutは重要な意義を有すると考えられる.
Practice臨床医学:一般
KeywordsSingle photon emission computed tomography, Dynamic scan, Tl-201, Ischemic heart disease.
English
TitleDynamic Single Photon Emission Computed Tomography of Tl-201 with Exercise Loading
SubtitleOriginal Articles
AuthorsHarutoshi KOIDE, Yoshiharu YONEKURA, Tohru FUJITA, Kanji TORIZUKA, Ryuji NOHARA, Tetsuo FUDO, Hirofumi KAMBARA, Chuichi KAWAI, Yutaka KONISHI, Toshihiko BAN
Authors(kana)
OrganizationKyoto University School of Medicine
JournalThe Japanese Journal of nuclear medicine
Volume23
Number11
Page1523-1531
Year/Month1986/11
ArticleOriginal article
PublisherTHE JAPANESE SOCIETY OF NUCLEAR MEDICINE
Abstract[Summary] : Single photon emission computed tomography (SPECT) with Tl-201 has been reported to provide accurate means for diagnosis of coronary artery disease (CAD) . The purpose of this study is to examine the serial changes in regional myocardial activity of Tl-201 injected during exercise loading in CAD using a multidetector SPECT system. Four cases without coronary stenosis (N) and 17 patients with CAD including 9 cases with prior myocardial infarction (MI) were studied. TI-201 was injected during submaximal exercise loading with a bicycle ergometer. Serial dynamic SPECT scan was performed every 5 min until 30 min after injection, followed by additional 3 scans for 10 min at 1 hr, 2 hr and 3 hr after injection. These SPECT images were corrected for the acquisition time, but no corrections were made for photon attenuation and scattering. N revealed uniform distribution throughout the study, and rapid washout was observed from the early period in 3/4 cases (10 to 24% for initial 25 min) . CAD showed various patterns of abnormal distribution and washout. In addition, the changes in regional distribution of Tl-201 were observed during the early period. These preliminary results indicate the significance of the early washout during the 30 min after injection of Tl-201, and careful consideration should be taken in calculating the washout rate by a conventional SPECT system with a rotating gamma camera.
PracticeClinical medicine
KeywordsSingle photon emission computed tomography, Dynamic scan, Tl-201, Ischemic heart disease.