Japanese |
Title | 心筋梗塞診断における 201Tl 心筋 ECT の臨床的評価 |
Subtitle | 原著 |
Authors | 井上登美夫*, 石原十三夫*, 山川通隆*, 玉木良雄*, 野崎美和子*, 永井輝夫* |
Authors(kana) | |
Organization | *群馬大学医学部放射線医学教室 |
Journal | 核医学 |
Volume | 19 |
Number | 8 |
Page | 1159-1166 |
Year/Month | 1982/9 |
Article | 原著 |
Publisher | 日本核医学会 |
Abstract | 「要旨」 回転型ガンマカメラによる 201Tl 心筋 ECT について, 心筋梗塞診断における臨床的有用性を検討した. 心筋梗塞33例を含む61例を対象に, planar image撮像後心筋ECTを施行した. 心筋梗塞に対する診断能をplanar imageと対比した結果, 有病正診率 (sensitivity) 無病正診率 (specificity) 総合正診率 (accuracy) は, planar imageでおのおの75.8%, 92.9%, 83.6%であったのに対し, ECTでは96.9%, 78.6%, 88.5%であった. ECTは有病正診率は明らかに向上するが, 無病正診率は低下し, 総合正診率としてはplanar imageに勝っていた. 心筋梗塞診断に際しては, 3種の断層面 (体軸横断, 矢状断, 前額断) を総合的に判定する必要があると思われた. また, ECT上の梗塞巣のひろがりは心電図所見と比較的よく一致した. |
Practice | 臨床医学:一般 |
Keywords | SPECT, Tl-201 myocardial imaging, Myocardial infarction, Rotating gamma camera |
English |
Title | Clinical Evaluation of Single-photon Emission Computed Tomography for Tl-201 Myocardial Imaging : Clinical Efficacy for Myocardial Infarction |
Subtitle | Original Articles |
Authors | Tomio INOUE, Tomio ISHIHARA, Michitaka YAMAKAWA, Yoshio TAMAKI, Miwako NOZAKI, Teruo NAGAI |
Authors(kana) | |
Organization | Department of Radiology, Gunma University, School of Medicine |
Journal | The Japanese Journal of nuclear medicine |
Volume | 19 |
Number | 8 |
Page | 1159-1166 |
Year/Month | 1982/9 |
Article | Original article |
Publisher | THE JAPANESE SOCIETY OF NUCLEAR MEDICINE |
Abstract | [Summary] Single-photon emission computed tomography (SPECT) for Tl-201 myocardial imaging using a rotating gamma camera was evaluated for clinical diagnostic efficacy of myocardial infarction. Thirty-three cases with prior myocardial infarction and 28 cases without myocardial infarction were injected with 2-4mCi of Tl-201 at rest. Planar imaging was performed for 5 views (ANT, LAO-30, 45, 60, L-LAT) and followed by SPECT. Overall time of the studies was within one hour. Results were as follows : (1) Sensitivity, specificity and overall accuracy for myocardial infarction diagnosis of SPECT system showed 96.9%, 78.6% and 88.5% respectively. In comparison with planar imaging, SPECT significantly improved sensitivity, however decreased specificity and slightly improved accuracy. (2) Overall interpretation of transaxial, coronal and sagittal images were required for the detection of myocardial infarction. (3) SPECT images showed more clearly findings of infarction than planar imaging and extension of myocardial infarction on SPECT images showed relatively well correlation with ECG diagnosis. |
Practice | Clinical medicine |
Keywords | SPECT, Tl-201 myocardial imaging, Myocardial infarction, Rotating gamma camera |