Title新副腎スキャン用剤6-methyl-75Se-selenomethyl-19-norcholest-5(10)-en-3β-ol(75Se-Scintadren) と6β-iodomethyl-19-norcholest-5(10)-en-3β-ol(131I-Adosterol) の比較検討
Subtitle原著
Authors瀬戸光**, 二谷立介*, 森厚文*, 小泉潔*, 久田欣一*
Authors(kana)
Organization*金沢大学医学部核医学教室, **現:富山医科薬科大学放射線医学教室
Journal核医学
Volume16
Number2
Page183-189
Year/Month1979/4
Article原著
Publisher日本核医学会
Abstract「要旨」新副腎スキャン用剤, 75Se-Scintadrenについてラットによる実験と臨床使用を行ない, 131I-Adosterolと比較検討を試みた. 投与後第7日ではラット副腎摂取率は131I-Adosterolに比べて約40%, 副腎・肝臓放射能比は約30%と低値を示した. 臨床的にも第5日以降に副腎スキャンを撮像した方がよいことが判った. しかし人間における75Se-Scintadrenの副腎摂取率は約0.20〜0.41%doseであり, 131I-Adosterolとほぼ同じ値であった. シンチレーションカメラのカウント効率は75Seでは131Iの約2.3倍であり, 1週間後の減衰を考慮すると, 75Se-Scintadrenの投与量は131I-Adosterolを1mCiとすれば約1/4の250〜200μCi程度でよいことが判った. 副腎の被曝線量をラットのデータおよび人間の副腎摂取率から算出したが, いずれの値も投与量あたり, 75Se-Scintadrenの方が少なかった.
Practice臨床医学:一般
KeywordsAdrenal scan, 75Se-Scintadren, 131I-Adosterol
English
TitleComparison of a New Adrenal Scanning Agent, 6-Methyl-75Se-Selenomethyl-19-Norcholest-5(10)-en-3β-ol(75Se-Scintadren) and 6β-Iodomethyl-19-Norcholest-5(10)-en-3β-ol(131I-Adosterol)
SubtitleOriginal Articles
AuthorsHikaru SETO, Ryusuke FUTATSUYA, Hirofumi MORI, Kiyoshi KOIZUMI, Kinichi HISADA
Authors(kana)
OrganizationDepartment of Nuclear Medicine, School of Medicine, Kanazawa University
JournalThe Japanese Journal of nuclear medicine
Volume16
Number2
Page183-189
Year/Month1979/4
ArticleOriginal article
PublisherTHE JAPANESE SOCIETY OF NUCLEAR MEDICINE
Abstract[Summary] Tissue distribution study in rats and adrenal uptake in humans were carried out with 75Se-Scintadren and 131I-Adosterol. At Day 7, concentration of 75Se-Scintadren in the adrenals was 8.9% kg dose/gm, which is approximately 40% of 131I-Adosterol and adrenal-to-liver concentration ratio was about 30% of 131I-Adosterol in rats. From the rat data and sequential adrenal uptake measurement in humans, it is recommended to take human adrenal images at 5 days later after a dose administration. However there are several advantages of 75Se-Scintadren versus 131I-Adosterol. On the contrary to the rat data, adrenal uptake in humans was calculated about 0.20-0.41% dose, which is nearly as same as that of 131I-Adosterol. Furthermore, counting efficiency of 75Se with a scintillation camera is 2.3 times that of 131I. The advantages are as follows : (1) Administered dose can be reduced one-fourth of 131I-Adosterol. (2) Estimated absorbed doses of adrenals were 99.8 rads/mCi extrapolated from the rat data and 31.6-63.2 rads/mCi from the human data, which are significantly less than that of 131I-Adosterol per administered dose. (3) No thyroid-blocking is required. (4) Shelf-life is longer than that of 131I-Adosterol.
PracticeClinical medicine
KeywordsAdrenal scan, 75Se-Scintadren, 131I-Adosterol